ROOT LOCUS LABSDATA CENTER THERMAL ENGINEERING Talk to an engineer
Liquid cooling for AI and hyperscale data centers

Cooling, engineered like a control system.

Root Locus Labs builds coolant distribution units for direct-to-chip liquid cooling and immersion cooling, run by an optimal control based cooling law and designed against a digital twin of your facility.

Discuss your project Explore our CDU in 3D
UNSTABLE σ jω breakaway break-in zero −∞ K: 0 → ∞ · one pole ends at the zero, one at −∞
DCLC CDUsImmersion coolingOptimal controlData center digital twinHVDC architecture
Solutions · Hardware

Heat removal at rack densities air cannot reach.

PRODUCT LINE A

CDUs for direct-to-chip liquid cooling

Coolant distribution units that move heat from cold plates on CPUs and GPUs to the facility water loop, holding supply temperature, pressure and flow steady as IT load swings.

  • In-rack and in-row configurations
  • Redundant pumps and filtration, hot-swappable service parts
  • Loop monitoring: ΔT, ΔP, flow, leak detection
  • Capacity up to 1.5 MW per unit
See inside the CDU
PRODUCT LINE B

Immersion cooling systems

Servers submerged in dielectric fluid, with heat carried out through a dedicated CDU and heat exchanger. Built for high-density AI clusters and sites where fan power and noise need to go.

  • Single-phase tank systems with integrated fluid management
  • Fan-less server operation
  • Fluid temperature control matched to hardware limits
Inside our CDU · Interactive

Follow the coolant from facility water to the chip.

Hydraulics on one side, power and controls on the other. Drag the model to look around, or click a part to see what it does.

Facility supply Facility return Rack supply Rack return
Drag to rotate · click a part
Services · Engineering

From the chip to the switchgear.

We work across the thermal and electrical chain, so cooling and power are designed together instead of patched together.

THERMAL

Thermal optimization

Hot-spot analysis, coolant loop sizing, setpoint tuning and air-to-liquid transition planning for new and existing halls.

ENERGY

Energy optimization

Cut pump, chiller and fan energy and lower PUE by running the cooling plant at the warmest safe setpoints the load allows.

ELECTRICAL

HVDC electrical architecture

High-voltage DC distribution design for high-density racks: fewer conversion stages, lower losses and less copper.

Technology · Software

Smarter control. Designs tested before they are built.

Optimal control based cooling law

Our cooling controller is built on optimal control methods. It keeps chips within their thermal limits while using as little pumping and cooling energy as possible, for better thermal efficiency across the whole loop.

Data center digital twin

A simulation of your facility's thermal behaviour, from racks and cold plates to CDUs and heat rejection. We run real-world load scenarios through it during design. Pick one to see what we test.

Rack load jumps from idle to full in seconds. We check that chip temperatures stay within limits while the controller responds.

Why Root Locus Labs

Our own IP, built and supported close to you.

We design our hardware and write our control software in-house, and we build through a local supply chain network. That shapes four things you will notice.

Cost effective

No licensing layers and local sourcing keep the total cost of the system down.

Shorter lead times

Parts and assemblies come from nearby partners, not long import queues.

Easy servicing

Spares are stocked locally and units are designed for quick field replacement.

Direct support

You talk to the engineers who designed the hardware and wrote the code.

How a project runs

Simulate, build, commission, then keep improving.

  1. STEP 1ModelBuild the digital twin from your layout, IT load profile and site conditions.
  2. STEP 2DesignSize CDUs, loops and power distribution, and test them against load scenarios.
  3. STEP 3DeployManufacture, install and commission with our local supply and field teams.
  4. STEP 4OptimizeOur optimal controller runs the plant live, and we tune it as your load grows.
Contact

Planning a liquid-cooled hall?

Tell us about your rack density, site and timeline. An engineer will get back to you with a first assessment.